Filter Results By:

Products

Applications

Manufacturers

Current Probes

measure AC or AC-DC amperage without contacting conductors.

See Also: Current Sensors


Showing results: 196 - 210 of 278 items found.

  • Complete Graphical Power Quality Analysis System

    PK5064-PRO+ - Summit Technology, Inc.

    The PK5064-PRO+ is the top choice for comprehensive power quality studies, energy audits, load studies, harmonic analysis, and more. Wide-range flexible current probes allow you to get into tight and confined spaces, wrap around large conductors, and measure almost any AC circuit that comes your way.

  • Mini Appliance Checker

    880 AT - Standard Electric Works Co., Ltd

    ● The 880 AT is a simplified Version of an appliance tester which use low voltage and low current to perform it's checks.● Application Example The appliance is plugged into the mini appliance checker, then the probe make contact with the protective conductor.● Other appliance checking Washing Machine Toaster Iron Dish Washer Stove

  • Cryogenic 4K Probe Cards

    Celadon

    Over the last 20 years the Celadon Engineering team has developed an expertise in cryogenic materials which has resulted in a solid reputation in the industry for producing extremely stable cryogenic on-wafer probe cards as well as DUT probing solutions. These Cryogenic probe cards have all the benefits of Celadon’s Crash Resistant™ probe technology but with the ability to probe as cold as humanly possible. Celadon’s cryogenic solutions vary from standard VersaTile™ footprints which interface to positioners to innovate custom PCB based designs to allow for flexibility when testing at these very cold temperatures. Lakeshore cryogenic wire is used in standard DC solutions for high density cable-out designs to support high pin count applications. During the development process, Celadon works closely with the cryogenic prober vendor to ensure the integrated solution is optimized for current and future testing needs.

  • Handheld Gauge for Nondestructive Coating Thickness Measurement

    PHASCOPE PMP10 - Helmut Fischer AG

    Handheld gauge for rapid and precise coating thickness measurement according to the phase sensitive eddy current method DIN EN ISO 21968Copper thickness measurement on pc-boards (probe ESD20Cu with 60 kHz or 240 kHz)Copper plating in through-holes of pc-boards (probe ESL080)Thickness measurement of metallic coatings on ferrous, non-ferrous metallic or electrically non-conductive partsDelivery with PC software FISCHER DataCenter with the following functionality: Transferring and archiving measurement data, comprehensive statistical and graphical evaluations, easy creation and printing of inspection reports

  • Localized Electrochemical Impedance Spectroscopy

    VS-LEIS - Ametek Scientific Instruments

    The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.

  • Loop and Line Powered Level Switch

    Safety IntelliPoint - AMETEK Drexelbrook

    The Safety IntelliPoint level switch provides a capacitance probe level switch with either a current output or relay contacts and “On-Board” self-diagnostics to ensure reliability. This SIL Intellipoint conforms to SIL 2 specifications providing the ultimate in level switch integrity and level sensing elements for a wide variety of temperatures, pressures, and materials.

  • Complete Power Quality Analysis System

    PK4564 - Summit Technology, Inc.

    PK4564 complete Power Quality Analysis System includes PS4550 Power Quality Analyzer with extended memory, AC charger, Quick-Start manual, deluxe voltage leads, four eFX6000 flexible current probes, SD memory card, CAS3 hard-shell carrying case, PSM-A Software, and 1-year deluxe warranty.

  • Temperature Logger with Integral Stab Probe

    TV-4076 - Gemini Data Loggers Ltd.

    Temperature recorder with integral stab probe LCD display of current readings 30,000 readings capacity High accuracy and reading resolution Fast data offload Splashproof case Low battery monitor and battery low indicator Programmable alarms Optional audible alarm box USB and serial download cables

  • Near Field Probes 30 MHz up to 3 GHz

    RF2 set - Langer EMV-Technik GmbH

    The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • Handheld Gauge for Nondestructive Coating Thickness Measurement

    PHASCOPE PMP10 DUPLEX - Helmut Fischer AG

    Handheld gauge for rapid and precise measurement of duplex-coatings (for the simultaneous measurement of lacquer and zinc or of lacquer/Al)Probe ESG20 uses measuring principles according DIN EN ISO 21968 (phase sensitive eddy current); DIN EN ISO 2178 (magnetic induction); DIN EN ISO 2360 (amplitude eddy current).Delivery with PC software FISCHER DataCenter with the following functionality: Transferring and archiving measurement data, comprehensive statistical and graphical evaluations, easy creation and printing of inspection reports

  • Isolated Hall Effect Current Sensors

    Vektrex Electronic Systems

    Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.

  • Shaft Voltage Tester™ Digital Oscilloscope

    AEGIS® - Electro Static Technology

    Digital Oscilloscope and Multimeter with Conductive Microfiber Probe Tips. Is your motor safe from destructive shaft voltages? For the first time you can get all of the tools to find out in one place. The AEGIS® Shaft Voltage Tester™ Digital Oscilloscope bundle includes the AEGIS-OSC-9100 100 MHz digital osciloscope, shaft voltage probe tips, and a shaft grounding simulator. Armed with these tools, you can quickly and easily find whether your motors are at risk of premature bearing failure due to VFD-produced bearing currents.

  • Temperature Transmitter

    T4111 - COMET SYSTEM, s.r.o.

    Transducer is designed for temperature measurement at C or F by means of an externaltemperature probe with Pt1000 sensor. Measured temperature is converted to linearized unified signal 4-20 mA. Measured values are displayed on LCD display. It is possible to switch OFF theLCD at all. Current loop has two-wire connection and requires power from evaluation device.

  • 600A True RMS AC Clamp Meter + NCV

    Extech MA620 - Extech Instruments Corporation

    MA620 is a True RMS, autoranging AC clamp meters offer plant maintenance techs, electrical troubleshooters, and DIYers a test instrument that delivers a combination of high performance and exceptional value. In addition to a host of advanced multimeter and current measurement capabilities, it also has a built-in, non-contact (NCV) voltage detector. You can select auto- or manual-ranging modes, measurement functions cover all types of troubleshooting over and above noninvasive current probe measurements: voltage, resistance, capacitance, frequency, duty cycle, diode and continuity tests. Even measure temperature with the supplied Type K bead wire probe. Complete with test leads, general purpose Type K bead wire temperature probe, 9V battery and carrying case.

  • MPI Automated Probe Systems

    MPI Advanced Semiconductor Test

    MPI’s 200 mm and 300 mm automated probe systems are dedicated and designed to address current and future requirements for all facets of Device Characterization for Modeling and Technology/Process Development, Failure Analysis, Design Verification, IC engineering, Wafer Level Reliability as well as special requirements for MEMS, High Power, RF and mmW device testing.

Get Help